TIDA-00368: The TIDA-00368 reference design provides a reference solution for interfacing current output Hall sensors and current transformers to differential ADC (standalone and integrated into MCU). The differential signal conditioning circuit is designed to measure motor current with an accuracy of ±0.5% across operating temperature range from -25°C to +75°C. The output common-mode voltage of the differential amplifier can be selected to either 1.25V or 2.5V.
TIDA-00178: The TIDA-00178 reference design is an EMC compliant industrial interface to Sin/Cos position encoders. Applications include industrial drives, which require accurate speed and position control. The design utilizes a 16-bit dual sample ADC with drop-in compatible 14- or 12-bit versions available, allowing for optimization of performance and cost. TIDA-00178 provides a direct connection to Sitara AM437x using SPI and QEP. For quick evaluation it features a 60-pin connector which directly fits the AM437x IDK. An example firmware for Sitara AM437x IDK is provided, which outputs the measured angle from the Sin/Cos encoder with up to 28-bit resolution through the Sitara’s USB virtual COM port.
TIDA-00316: The TIDA-00316 reference design provides a reference solution for interfacing current output Hall sensors and current transformers to Pseudo-differential ADC (standalone and integrated into MCU). Two variants of signal conditioning circuits are designed to measure motor current using bipolar and unipolar supply voltages respectively. Both the signal conditioning circuits provide current measurement accuracy within ±0.5% for an operating temperature range from -25°C to +75°C.
TIDA-00316: The TIDA-00316 reference design provides a reference solution for interfacing current output Hall sensors and current transformers to Pseudo-differential ADC (standalone and integrated into MCU). Two variants of signal conditioning circuits are designed to measure motor current using bipolar and unipolar supply voltages respectively. Both the signal conditioning circuits provide current measurement accuracy within ±0.5% for an operating temperature range from -25°C to +75°C.
TIDA-01063: TIDA-01063 is a reference design for current sensing using a PCB Rogowski Coil sensor to achieve very good linearity for wide measurement range at very low system BOM cost. PCB Rogowski sensor is advantageous for isolated current measurement due to very high bandwidth of 20 MHz and fast settling time of 50 ns. Auto-zeroing, 12nV/√Hz noise density of INA188 makes it suitable to achieve 12 bit system resolution for full scale current of 1000 A. Using simple IIR digital integration algorithm and scalable sampling rate it is possible to achieve better magnitude and phase response.
TIDA-00368: The TIDA-00368 reference design provides a reference solution for interfacing current output Hall sensors and current transformers to differential ADC (standalone and integrated into MCU). The differential signal conditioning circuit is designed to measure motor current with an accuracy of ±0.5% across operating temperature range from -25°C to +75°C. The output common-mode voltage of the differential amplifier can be selected to either 1.25V or 2.5V.
TIDA-00178: The TIDA-00178 reference design is an EMC compliant industrial interface to Sin/Cos position encoders. Applications include industrial drives, which require accurate speed and position control. The design utilizes a 16-bit dual sample ADC with drop-in compatible 14- or 12-bit versions available, allowing for optimization of performance and cost. TIDA-00178 provides a direct connection to Sitara AM437x using SPI and QEP. For quick evaluation it features a 60-pin connector which directly fits the AM437x IDK. An example firmware for Sitara AM437x IDK is provided, which outputs the measured angle from the Sin/Cos encoder with up to 28-bit resolution through the Sitara’s USB virtual COM port.
TIPD156: This Verified TI Precision Design implements a low-drift, bi-directional, low-side, single-supply current sensing solution that measures load currents from -2.5 A to +2.5 A. The output range is from 250 mV to 2.75 V, with 0 A current centered at 1.5 V. To achieve low-drift performance, the solution utilizes the INA213B and REF2030. The design’s functionality and performance were verified by fabricating a PCB and measuring results over temperature from -40 °C to 125 °C.
TIPD156: This Verified TI Precision Design implements a low-drift, bi-directional, low-side, single-supply current sensing solution that measures load currents from -2.5 A to +2.5 A. The output range is from 250 mV to 2.75 V, with 0 A current centered at 1.5 V. To achieve low-drift performance, the solution utilizes the INA213B and REF2030. The design’s functionality and performance were verified by fabricating a PCB and measuring results over temperature from -40 °C to 125 °C.