无法从文档中提取型号,请重试

Update your browser

Your browser (Internet Explorer) is out of date.

Update your browser for more security, comfort and the best experience for this site.

首页 > 电子元器件选型 > 微控制器和处理器 > 其他 uPs/uCs/外围集成电路

MSP430F6779IPEUR

加入BOM

MSP430F6779IPEUR
已加入BOM:

Texas Instruments

Polyphase metering SoC with 7 Sigma-Delta ADCs, LCD, real-time clock, AES, 512KB Flash, 32KB RAM 128-LQFP -40 to 85

市场均价:
¥91.5544
市场总库存:
-
生命周期状态: Active
技术详情
价格 & 库存
替代料

参考设计

(8)
TIDA-00222 Measurement Module for Branch Circuit Power Monitor Reference Design | TI.com
TIDA-00222: This reference design targets measurement accuracy across the rated current range while at the same time being a cost efficient solution. This is achieved by using a highly integrated SoC device which has up to 7 channels of the 24-bit Delta-Sigma ADCs available for current measurement. For voltage measurement a 10-bit SAR ADC is used. With both current and voltage available, power measurement can now be made. This solution also has several options for communication supported such as UART, JTAG, etc. Applications include load management, sub-panels, etc.
Measurement Module for Branch Current Monitor
TIDA-00221: This reference design is designed to measure only branch current and is created for accuracy across the majority of the rated current range while at the same time being cost efficient. This is achieved by using a highly integrated SoC device which has up to 7 channels of the 24bit Delta-Sigma ADCs available for current measurement. This solution also has several options for communication supported. such as UART, JTAG, etc. Applications include load management, sub-panels, etc.
Three-Phase Metrology With Enhanced ESD Protection and Tamper Detection Reference Design
TIDM-3PHMTR-TAMP-ESD: This design implements an ANSI/IEC Class 0.2 three-phase energy meter with enhanced ESD protection. The design also features tamper detection to limit the feasibility of energy theft and communications through ZigBee™ connectivity. The e-meter SoC is used to perform all metrology functions and sends active power results to the CC2530EM add-on board. Developers can use the companion In Home Display TI Design (TIDM-LOWEND-IHD) to display results remotely. This reference design uses the MSP430F67791A. This reference design can also be used with the MSP430F67791,MSP430F6779 and MSP430F6779A.
TIDM-3PHMTR-TAMP-ESD Three-Phase Metrology With Enhanced ESD Protection and Tamper Detection Reference Design | TI.com
TIDM-3PHMTR-TAMP-ESD: This design implements an ANSI/IEC Class 0.2 three-phase energy meter with enhanced ESD protection. The design also features tamper detection to limit the feasibility of energy theft and communications through ZigBee™ connectivity. The e-meter SoC is used to perform all metrology functions and sends active power results to the CC2530EM add-on board. Developers can use the companion In Home Display TI Design (TIDM-LOWEND-IHD) to display results remotely. This reference design uses the MSP430F67791A. This reference design can also be used with the MSP430F67791,MSP430F6779 and MSP430F6779A.
TIDM-THREEPHASEMETER-F6779 High Accuracy Three-Phase Electricity Meter with Tamper Detection | TI.com
TIDM-THREEPHASEMETER-F6779: The design implements a highly accurate three-phase electric meter system using the MSP430F6779 smart meter SoC. It exceeds all of the requirements for ANSI C12.20 and IEC-62053 Class 0.2 meters. The F6779 SoC is the most integrated polyphase e-meter SoC with 512KB flash. This allows developers to create a true single-chip smart e-meter with the highest performance and accuracy. In addition, this EVM has tamper detection capabilities which assist the engineer’s development of methods to prevent theft of electricity from utilities.
Measurement Module for Branch Circuit Power Monitor Reference Design
TIDA-00222: This reference design targets measurement accuracy across the rated current range while at the same time being a cost efficient solution. This is achieved by using a highly integrated SoC device which has up to 7 channels of the 24-bit Delta-Sigma ADCs available for current measurement. For voltage measurement a 10-bit SAR ADC is used. With both current and voltage available, power measurement can now be made. This solution also has several options for communication supported such as UART, JTAG, etc. Applications include load management, sub-panels, etc.
High Accuracy Three-Phase Electricity Meter with Tamper Detection
TIDM-THREEPHASEMETER-F6779: The design implements a highly accurate three-phase electric meter system using the MSP430F6779 smart meter SoC. It exceeds all of the requirements for ANSI C12.20 and IEC-62053 Class 0.2 meters. The F6779 SoC is the most integrated polyphase e-meter SoC with 512KB flash. This allows developers to create a true single-chip smart e-meter with the highest performance and accuracy. In addition, this EVM has tamper detection capabilities which assist the engineer’s development of methods to prevent theft of electricity from utilities.
TIDA-00221 Measurement Module for Branch Current Monitor | TI.com
TIDA-00221: This reference design is designed to measure only branch current and is created for accuracy across the majority of the rated current range while at the same time being cost efficient. This is achieved by using a highly integrated SoC device which has up to 7 channels of the 24bit Delta-Sigma ADCs available for current measurement. This solution also has several options for communication supported. such as UART, JTAG, etc. Applications include load management, sub-panels, etc.